Abstract

Spheres coated with antibodies specific for myosin were used to detect myocardial cell membrane disruption by scanning electron microscopy. Injury in a population of cultured myocytes as then followed and measured by fluorescence-activated cell sorting. This approach provides a unique method for quantitating the evolution of myocardial injury and potentially for assessing the efficacy of interventions aimed at myocardial protection.