Table 2.

Parameters of fitted equations for rhythms of period mutants. The parameters of the fitted equation of Fig. 3 are listed. Standard deviations of parameters were of similar magnitude to those in Table 1.

MutantPeriod T (hours)Phase I (CT)Doubling time D (hours)Rhythmic component AConstitutive component CA/C
SP2023.310.912.61.411.10.12
SP2221.310.412.75.90.78.9
LP2730.110.413.45.427.20.20
p3027.711.913.817.525.40.69